- Reach into the machine to check the compressor
- It should be vibrating if the compressor is on
- If it is not vibrating, the compressor is most likely blown, follow these next steps to remove it
- Power the Machine down
- Pull the Compression Unit out
- Unplug the 3 wires: the main power wire, the relay wire, and the main temperature wire
- Push them through the fire wall so they are out of the way
- Remove the two screws
- If the bracket at the top is plastic it should slide right out now
- If it is a metal bracket, you have to remove the cone before you can take the deck out
- You remove it by unscrewing the metal cone
- To remove the deck, unscrew the two screws on the sides, then grip the bracket behind the deck to remove it
- With the deck removed you can see what specifically is not working on the deck
- It could be the compressor, the fans, or the coolant
- You can plug it in outside the machine to examine more closely what is not working
- If the fans are not working you can remove and replace them directly on the refrigeration deck
- You have to have a license if the compressor is broken, so you will have to get a professional
- How to put the deck back into the machine
- Make sure your wires are still out of the way
- It will slide right back in
- Screw the deck back into place
- If your machine has the metal bracket make sure to screw it back in
- Pull the 3 wires back through and plug them in